IMPROVIMG THE DLC (DISTRIBUTION LINE CARRIER) SYSTEM BEHAVIOR THROUGH MEIUM VOLTAGE NETWORKS (MVNs)

Authors

Faculty of Engineering Minia University, Egypt

Abstract

With the great available technological advances, MVNs are still difficult to control, because of their dense meshing and their automation is very cost-intensive. There are generally no communication cables in the MVNs' equipment such as the MV transformer and distribution stations. One of the costless technologies used to communicate between the MVNs' equipment and the control center of a SCADA system is the DLC communication technology, where, data transfer occurs directly on the medium voltage cables, i.e. on the conductors of the underground and/or the overhead cables or on the shields of the underground cables. However, the DLC system suffers from many problems concerned in MVNs. In addition, the design of the DLC system itself has some defects, which affect its performance and stability. Here, we explain with simulation the exits instability margins of the operation of the DLC system to help us how we can improve the stability margins of the system to achieve a good performance

Keywords

Main Subjects


[1]SIEMENS AG: "Equipment Manual DCS3000", Edition A2.4.0, August 2002.
[2]  J. G. Bolger, F. A. Kirsten and L. S. Ng, "Inductive power coupling for an electric highway system," 28th IEEE Vehicular Technology Conference, Denver, Colorado, USA, 1978, pp. 137-144.
doi: 10.1109/VTC.1978.1622522.
[3] Patrick MULROY and Ian GILBERT, “COMPARISON OF COUPLING METHODS IN MV EQUIPMENT FOR POWERLINE COMMUNICATIONS”, 21st International Conference on Electricity Distribution, Paper 0870, Frankfurt, 6-9 June 2011.
[4]  H. F. Abdel-Ghaffar and M. F. Abdel-Magied, "Performance analysis of DCS3000 in closed loop control systems," in 2006 American Control Conference, 2006, p. 6 pp.
[5]  Mirko Obradovic and Fotini-Niovi Pavliodou: “Power Line Communication Based on OFDM”, Paper, Aristotel University, Thesaloniki, Greece, 2002.
[6]  Charles L., Phillips and Henry T., Nagle: "Digital Control System Analysis and Design", Prentice-Hall, Inc., 984, chapters 3, 4 and 5.
[7]   Antoniou, A.: "Digital Filters: Analysis DesignApplications", McGraw-Hill Inc., Second edition, 1993, chapters 2, 3 and 7.
[8] Holmgren, R. A First Course in Discrete Dynamical Systems. Springer-Verlag, New York 1994).
[9]   MathWorks, Inc.: "Matlab R2016a Software Package User Guide", 2016, (MATLAB Help Version R2016a CD).
[10]  H. H. Vo, P. Brandstetter, C. S. T. Dong, T. Q. Thieu, and D. H. Vo, “An implementation on MATLAB software for stability analysis of proportional controllers in linear time invariant control systems,” in New Advances in Information System and Technologies. Cham, Switzerland: Springer, Mar. 2016, pp. 671–680.
[11]Y. Li, B. Tian, K. Yi, and Q. Yu, “An effective approach for parameter determination of the digital phase-locked loop in the z-domain,” Digit. Signal Process. vol. 54, pp. 87–94, Jul. 2016.
[12] Yunhua Li, Bin Tian, Kechu Yi, Member, IEEE, and Quan Yu, “Efficient Parameter Design Guideline for Closed-Loop Synchronization Architectures”, IEEE Wireless Communication Letters, VOL. 5, NO. 6, December 2016.